Design of the new superconducting microprobe system in Munich
Titel Konferenzpublikation:
5th International Conference of Nuclear Microprobe Technology and Applications
Zeitschrift:
Nuclear Instruments and Methods in Physics Research Section B
Jahrgang:
130
Heftnummer:
1-4
Konferenztitel:
International Conference on Nuclear Microprobe Technology and Applications (5., 1996, Santa Fe, NM)
Tagungsort:
Santa Fe, NM
Jahr der Konferenz:
1996
Datum Beginn der Konferenz:
11.11.1996
Datum Ende der Konferenz:
15.11.1996
Jahr:
1997
Seiten von - bis:
51-56
Sprache:
Englisch
Stichwörter:
Aberrations ; Magnetic lenses ; Niobium alloys ; Particle accelerator accessories ; Particle beams ; Probes ; Superconducting magnets, Superconducting microprobe systems ; Tandem accelerators, Nuclear instrumentation
Abstract:
At the Munich 15 MV tandem accelerator a new two-stage microprobe system is under construction. It will demagnify a beam spot by a factor 200 in both transversal directions for ions up to an energy of 200 MeV · q2/A. The second stage of the system is a superconducting quadrupole doublet lens, with overlayed 2n-poles